Zaletov I. S., Sagaidachnyi A. A., Skripal A. V., Klochkov V. A., Mayskov D. I., Fomin A. V. Interrelation between pulse wave forms in the peripheral arteries registered by methods of impedance rheography and ultrasonic dopplerography. Izvestiya of Saratov University. Physics , 2023, vol. 23, iss. 1, pp. 24-36. DOI: 10.18500/1817-3020-2023-23-1-24-36, EDN: BHJEOX

This is an open access article distributed under the terms of Creative Commons Attribution 4.0 International License (CC-BY 4.0).
Published online: 
01.03.2023
Full text:
(downloads: 366)
Language: 
Russian
Article type: 
Article
UDC: 
537:612.1
EDN: 
BHJEOX

Interrelation between pulse wave forms in the peripheral arteries registered by methods of impedance rheography and ultrasonic dopplerography

Autors: 
Zaletov Ivan Sergeevich, Saratov State University
Sagaidachnyi Andrey Aleksandrovich, Saratov State University
Skripal Anatoly Vladimirovich, Saratov State University
Klochkov Viktor Alexandrovich, Saratov State Medical University named after V. I. Razumovsky
Mayskov Dmitriy Igorevich, Saratov State University
Fomin Andrey Vladimirovich, Saratov State University
Abstract: 

Background and Objectives: Impedance plethysmography and Doppler ultrasound, in most cases, are considered as independent methods for analyzing hemodynamics. This work shows the presence of similarities in the shape of pulse waves recorded by the two indicated methods at rest and during exercise tests. The dynamics of the volume and velocity of blood flow in the radial artery was studied at rest, during an occlusive test and a test with a deep breath. Materials and Methods: The method of impedance rheography was used to determine the dynamics of the blood volume in the artery, and the method of ultrasound dopplerography was used to determine the linear velocity of arterial blood flow. The equation that considers the irregular distribution of erythrocytes velocity in the cross-section of a blood vessel has been obtained for a correct quantitative description of the dynamics of the volumetric blood flow velocity. Results: It has been determined that both the deep breath test and the occlusive test lead to vasodilation of the radial artery. In this case, the test with deep breath causes the appearance of an additional peak in the diastole which agrees in time with the negative (retrograde) diastolic peak of the blood flow velocity. Comparative analysis of the integrated velocity and volume waves demonstrates phase matching and a linear dependence of the shape of these waves at rest which are disrupted during the deep breath test. Conclusions: The proposed equation for calculating volumetric blood flow enables one to study the processes of autoregulation of blood flow in vessels by controlling the balance of changes in blood volume and velocity by the methods of impedance rheography and ultrasound dopplerography and can potentially form the basis for the development of appropriate methods of functional diagnostics.

Acknowledgments: 
The study was supported by the Russian Science Foundation (project no. 21-75-00035).
Reference: 
  1. Huisman M. V., Böller H. R., ten Cate J. W., Vreeken J. Serial impedance plethysmography for suspected deep venous thrombosis in outpatients. New England Journal of Medicine, 1986, vol. 314, no. 13, pp. 823–828. https://doi.org/10.1056/NEJM198603273141305
  2. Liu S. H., Cheng D. C., Su C. H. A cuffless blood pressure measurement based on the impedance plethysmography technique. Sensors, 2017, vol. 17, no. 5, article no. 1176. https://doi.org/10.3390/s17051176
  3. Huynh T. H., Jafari R., Chung W. Y. Noninvasive cuffless blood pressure estimation using pulse transit time and impedance plethysmography. IEEE Transactions on Biomedical Engineering, 2018, vol. 66, no. 4, pp. 967–976. https://doi.org/10.1109/TBME.2018.2865751
  4. Soukup L., Hruskova J., Jurak P., Halamek J., Zavodna E., Viscor I., Vondra V. Comparison of noninvasive pulse transit time determined from Doppler aortic flow and multichannel bioimpedance plethysmography. Medical & Biological Engineering & Computing, 2019, vol. 57, no. 5, pp. 1151–1158. https://doi.org/10.1007/s11517-018-01948-x
  5. Mašanauskienл E., Sadauskas S., Naudžiūnas A., Unikauskas A., Stankevičius E. Impedance plethysmography as an alternative method for the diagnosis of peripheral arterial disease. Medicina, 2014, vol. 50, no. 6, pp. 334–339. https://doi.org/10.1016/j.medici.2014.11.007
  6. Kobrisev P. A., Tujkin T. S., Korzhenevskij A. V. Development of a non-contact human vital signs monitor. Journal of Radio Electronics, 2017, no. 4. Available at: http://jre.cplire.ru/jre/apr17/10/text.pdf (accessed 08 September 2022) (in Russian).
  7. Brown B. H., Pryce W. I. J., Baumber D., Clarke R. G. Impedance plethysmography: can it measure changes in limb blood flow. Medical and Biological Engineering, 1975, vol. 13, no. 5, pp. 674–682. https://doi.org/10.1007/BF02477325
  8. Tsoy M. O., Postnov D. E. Method for determining significant components for assessing pulse wave shape variability. Izvestiya of Saratov University. Physics, 2021, vol. 21, iss. 1, pp. 36–47 (in Russian) https://doi.org/10.18500/1817-3020-2021-21-1-36-47
  9. Zaletov I. S., Klochkov V. A., Sagaidachnyi A. A., Skripal An. V., Fomin A. V. Impedance rheography of peripheral arteries of a high degree of localization under the influence of a gravity probe. Metody komp’yuternoj diagnostiki v biologii i meditsine-2021: Sbornik statej Vserossijskoj shkoly-seminara [Methods of computer diagnostics in biology and medicine-2021 : Collection of articles of the All-Russian school-seminar]. Saratov, Saratovskiy istochnik Publ., 2021, pp. 27–31 (in Russian).
  10. Wilder-Smith E., Liu L., Ma K. T. M., Ong B. K. Relationship of inspiratory flow rate and volume on digit tip skin and ulnar artery vasoconstrictor responses in healthy adults. Microvascular Research, 2005, vol. 69, no. 1–2, pp. 95–100. https://doi.org/10.1016/j.mvr.2005.01.003 
  11. Allen J., Frame J. R., Murray A. Microvascular blood flow and skin temperature changes in the fingers following a deep inspiratory gasp. Physiological Measurement, 2002, vol. 23, no. 2, pp. 365. https://doi.org/10.1088/0967-3334/23/2/312
  12. Mayrovitz H. N., Groseclose E. E. Neurovascular responses to sequential deep inspirations assessed via laserDoppler perfusion changes in dorsal finger skin. Clinical Physiology and Functional Imaging, 2002, vol. 22, no. 1, pp. 49–54. https://doi.org/10.1046/j.1475-097x.2002.00404.x
  13. Sagaidachnyi A. A., Skripal A. V. Okklyuzionnaya proba: biofizicheskie mekhanizmy reaktsii, metody analiza, perspektivy primeneniya: uchebnoe posobie dlya studentov [Occlusion test: Biophysical reaction mechanisms, analysis methods, application perspectives: A manual for students]. Saratov, Saratovskiy istochnik Publ., 2019. 81 p. (in Russian).
  14. Anikina N. Y., Korovina V. A., Tarasova A. V., Ushakova N. Y., Yaroshenko Y. A. Gidrodinamika. Fizicheskie osnovy gemodinamiki: uchebno-metodicheskoe posobie [Hydrodynamics. Physical fundamentals of hemodynamics: An educational and methodical manual]. Arkhangelsk, Izdatelstvo Severnogo gosudarstvennogo meditsinskogo universiteta, 2021. 111 p. (in Russian).
  15. Bernstein D. P. Impedance cardiography: Pulsatile blood flow and the biophysical and electrodynamic basis for the stroke volume equations. Journal of Electrical Bioimpedance, 2010, vol. 1, no. 1, pp. 2–17. https://doi.org/10.5617/jeb.51
  16. Ramalli A., Aizawa K., Shore A. C., Morizzo C., Palombo C., Lenge M., Tortoli P. Continuous simultaneous recording of brachial artery distension and wall shear rate: A new boost for flow-mediated vasodilation. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2018, vol. 66, no. 3, pp. 463–471. https://doi.org/10.1109/TUFFC.2018.2889111
  17. Kubicek W. G., From A. H., Patterson R. P., Witsoe D. A., Castaneda A., Lillehei R. C., Ersek R. Impedance cardiography as a noninvasive means to monitor cardiac function. JAAMI: Journal of the Association for the Advancement of Medical Instrumentation, 1970, vol. 4, no. 2, pp. 79–84.
  18. Shimazu H., Yamakoshi K. I., Togawa T., Fukuoka M., Ito H. Evaluation of the parallel conductor theory for measuring human limb blood flow by electrical admittance plethysmography. IEEE Transactions on Biomedical Engineering, 1982, vol. 1, pp. 1–7. https://doi.org/10.1109/TBME.1982.324957
  19. Eicke B. M., Milke K., Schlereth T., Birklein F. Comparison of continuous wave Doppler ultrasound of the radial artery and laser Doppler flowmetry of the fingertips with sympathetic stimulation. Journal of Neurology, 2004, vol. 251, no. 8, pp. 958–962. https://doi.org/10.1007/s00415-004-0471-7 
Received: 
21.10.2022
Accepted: 
26.12.2022
Published: 
01.03.2023